.. Go  List PASS
FAIL
No load N/T 
  N/A
Model :                Date : 2023/5/4       Reference              
1.      Equipment :                                        
               (1)    AC Source : Chroma 6530                                    
              (2)    DC Load : Chroma 63102/63103                                  
                (3)    Oscilloscope : Keysight DSOX3034T                                      
                                           
2.      Test Condition :                                        
  (1)    AC Input Voltage : 90V / 264V                                    
  (2)    Input Frequency : 60Hz /50Hz                                    
  (3)    Load Condition : No load                                    
  (4)    Temperature :Room Ambient Temperature                                  
  (5)   Wavefrom Requirement  :  12V/5V/3.3V/Standby                                
                                           
3.      Spec :                                        
  No damage or hazardous condition should occur with all the DC output connectors disconnected from the load.                                        
  The output regulation shall also be within specification                                
                                           
4.     Test Result : PASS                            
90Vac/60Hz AC_on 90Vac/60Hz PS_on
tek00005.png
tek00006.png
(1) 12V (2) 5V (3) 3.3V (4) PG (1) 12V (2) 5V (3) 3.3V (4) PG
90Vac/60Hz AC_on 90Vac/60Hz PS_on
tek00027.png
tek00028.png
(1) -12V (2) 5Vsb (3) PG (1) -12V (2) 5Vsb (3) PG
264Vac/50Hz AC_on 264Vac/50Hz PS_on
tek00007.png
tek00008.png
(1) 12V (2) 5V (3) 3.3V (4) PG (1) 12V (2) 5V (3) 3.3V (4) PG
264Vac/50Hz AC_on 264Vac/50Hz PS_on
tek00025.png
tek00026.png
(1) -12V (2) 5Vsb (3) PG (1) -12V (2) 5Vsb (3) PG