Go  List       PASS                              
                            FAIL                              
Reset After Shutdown       N/T                               
                            N/A                              
Model :                Date : 2023/4/24         Reference                              
                                                           
1.      Equipment :                                                        
               (1)    AC Source : Chroma 6530                                                    
              (2)    DC Load : Chroma 63102/63103                                                  
                (3)    Oscilloscope : Tektronix TDS 5054B                                                        
                                                           
2.      Test Condition :                                                      
  (1)    AC Input Voltage : Min. and Max. of Input Voltage                                              
  (2)    Input Frequency : 60Hz /50Hz                                                  
  (3)    Load Condition : LD1 & LD2                                                  
  (4)    Temperature :Room Ambient Temperature                                                 
  (5)   Wavefrom Requirement  :  12V/PG/3.3V/Standby                                                
                                                           
3.      Spec :                                                        
If the power supply latches into a shutdown state because of a fault condition on its outputs, the power supply shall return to normal operation only after the fault has been removed and the PS_ON# has been cycled OFF/ON with a minimum OFF time of 1 second or remove the AC power cord for 30 seconds.                      
1. Removing AC input power, waiting for Standby to drop below 1.0V, then reapplying AC power. The falling time of Standby voltage from regulation drops to 1V shall not exceed than 30 sec.
2. Cycling the state of PS_ON from on to off to on. The minimum cycle time will be 1000mS.
                                     
4.      Test Result : PASS                      
                                                           
  Load Input Voltage Spec                      
90V 264V                      
AC - ON Load 1 Pass Pass The time it takes for Standby to drop below 1.0V
Load 2 Pass Pass
                                                       
                                                       
90Vac/60Hz Load2             90Vac/60Hz Load1                                    
tek00002.png
 
                                                         
         
tek00003.png
                       
                                 
                                 
                                 
                                 
                                 
                                       
                                       
                                       
                                       
                                       
                                       
                                       
                                       
                                       
                                       
(1) AC in (2) 12V (3) PG (4) 5Vsb           (1) AC in (2) 12V (3) PG (4) 5Vsb                                  
                                                           
264Vac/50Hz Load2             264Vac/50Hz Load1                                    
               
tek00004.png
                       
tek00001.png
 
                                     
                                       
                                       
                                       
                                       
                                       
                                       
                                       
                                       
                                       
                                       
                                       
                                       
                                       
                                       
                                       
(1) AC in (2) 12V (3) PG (4) 5Vsb           (1) AC in (2) 12V (3) PG (4) 5Vsb