Go  List       PASS                                          
                            FAIL                                          
Remote ON/OFF control       N/T                                           
                            N/A                                          
Model :                Date : 2023/5/8         Reference                                          
                                                                       
1.      Equipment :                                                                    
               (1)    AC Source : Chroma 6530                                                                
              (2)    DC Load : Chroma 63102/63103                                                              
                (3)    Oscilloscope : Tektronix TDS 5054B                                                                    
  (4)   DC Source : Agilent E3634A                                                                    
                                                                       
2.      Test Condition :                                                                  
  (1)    AC Input Voltage : Min. and Max. of Input Voltage                                                          
  (2)    Input Frequency : 60Hz /50Hz                                                              
  (3)    Load Condition : LD1 & LD2                                                              
  (4)    Temperature :Room Ambient Temperature                                                             
  (5)   Wavefrom Requirement  :  12V/PG/PSON                                                            
                                                                       
3.      Spec :                                                                    
The power supply DC outputs will be enabled when this signal is pulled low, below 0.8V. In the low state the 
input will not source more than 1mA of current. The DC outputs will be disabled when the input is driven higher 
than 2.0V, or open circuited.
Provisions for de-bouncing will be included in the –PS_ON circuitry to prevent the power supply from
oscillating on/off at startup.
                                                       
4.      Test Result : PASS                                                        
                                                                       
Load Input Voltage Spec                              
90V 264V                              
PS-ON  Threshold
( Turn-On )
Load 1 1.692V 1.689V 0.8 ~ 2.06V                                    
Load 2 1.59V 1.679V                                    
PS-OFF  Threshold
( Turn-Off )
Load 1 1.038V 1.041V                                    
Load 2 0.947V 1.043V                                  
                                                                       
90Vac/60Hz Load1 Turn_off           90Vac/60Hz Load1 Turn_on                                            
tek00014.png
 
              tek00015.png
 
                                                     
                                         
                                         
                                         
                                         
                                         
                                         
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
(1) PS_ON (2) PG               (1) PS_ON (2) PG                                                  
                                                                       
90Vac/60Hz Load2 Turn_off           90Vac/60Hz Load2 Turn_on                                            
                                                                       
tek00022.png
 
              tek00023.png
 
                                                     
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
                                                                       
  (1) PS_ON (2) PG               (1) PS_ON (2) PG                                                
                                                                       
264Vac/50Hz Load1 Turn_off         264Vac/50Hz Load1 Turn_on                                            
tek00016.png
 
             
tek00017.png
                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
(1) PS_ON (2) PG               (1) PS_ON (2) PG                                                  
                                                                       
264Vac/50Hz Load2 Turn_off     264Vac/50Hz Load2 Turn_on                                            
tek00000.png
 
             
tek00001.png
                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                   
                                                                       
(1) PS_ON (2) PG               (1) PS_ON (2) PG