Go  List       PASS          
                          FAIL          
Current Validation PS_ON       N/T           
                          N/A          
Model :              Date : 2023/5/6         Reference          
                                     
1.      Equipment :                                  
               (1)    AC Source : Chroma 6530                              
              (2)    DC Load : Chroma 63102/63103                            
                (3)    Oscilloscope : Tektronix TDS 5054B                                  
  (4)    Current Probe : Tektronix TCPA300/TCP303                                    
                                   
                                     
2.      Test Condition :                                
  (1)    AC Input Voltage : 90V/264V                            
  (2)    Input Frequency : 60Hz /50Hz                            
  (3)    Load Condition :  Load 1/MinLoad                            
  (4)    Temperature :Room Ambient Temperature                           
  (5)   Wavefrom Requirement  :  N.A                            
                                     
3.      Spec :                                  
In the low state the input will not source more than 4mA of current.                  
                                   
4.      Test Result : PASS                      
                       
  Vin
(V)
Remote Load condition PSON
Voltage
PS_ON Current(mA) PSON
Voltage
                   
                   
  90V/60Hz On  Load 1 0.4V< 1.0170 0.01904                  
  90V/60Hz On Load 2 0.9291 0.02137                  
  264V/50Hz On  Load 1 0.8575 0.02292                      
  264V/50Hz On Load 2 0.8286 0.0187      
                   
90V 60Hz PS_ON ON    Load1     264V 60Hz PS_ON ON    Load1                      
tek00004.png tek00005.png
 
                                   
                                     
                                     
                                     
                                     
                                     
                                     
                                     
                                     
                                     
90V 60Hz PS_ON ON    Load2     264V 60Hz PS_ON ON    Load2                      
tek00007.png