Go  List       PASS                        
                            FAIL                        
AC loss to PWR-OK hold-up Time ( T5)       N/T                         
                            N/A                        
Model :                Date : 2023/3/11       Reference                        
                                                     
1.      Equipment :                                                  
               (1)    AC Source : Chroma 6530                                              
              (2)    DC Load : Chroma 63102/63103                                            
                (3)    Oscilloscope : Tektronix TDS 5054B                                                  
                                                     
2.      Test Condition :                                                
  (1)    AC Input Voltage : Min. and Max. of Input Voltage                                        
  (2)    Input Frequency : 60Hz /50Hz                                            
  (3)    Load Condition : LD2 (or defined by customer)                                                
  (4)    Temperature :Room Ambient Temperature                                           
  (5)   Wavefrom Requirement  : VAC/PG/12V                                          
   
 
                                               
3.      Spec :                                                  
                                                   
                                                     
                                                     
                                                     
                                                     
                                                     
                                                     
                                                     
                                                     
                                                     
                                                     
                                                     
                                                     
4.      Test Result : PASS                                      
                                                     
Load Input Voltage Spec
90V 264V
Load2 17.0mS 16.9mS > 16mS
                                             
                                                     
                                                     
90Vac/60Hz LOAD2             264Vac/50Hz LOAD2                              
tek00000.png
 
               
tek00001.png
               
                     
                     
                     
                     
                     
                     
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
(1) AC in (2) PG (3) 12V             (1) AC in (2) PG (3) 12V